OEC Elite Large C-Arm for Sale, Lease or Rent
Request A Quote
Description
- 60kHz high frequency
- 15kW power
- Up to 120kVp
- Up to 75mA for radiographic film exposure
- Continuous high level fluoro (HLF) up to 20mA
- Digital spot up to 75mA
- Pulsed HLF up to 40mA
- Full power from standard wall outlet
- Patented battery buffered design
- Rotating anode X-ray tube
- 0.3mm and 0.6mm focal spots
- Anode heat capacity: 300,000 HU
- Anode cooling rate: 85,000 HU/min.
- Housing heat capacity: 1,600,000 HU
- Housing cooling: -9″ II = 22,500 HU/min, 12″ II = 22,500 HU/min
- Digitally adjusts image display for live and last image hold
- Automatic image update preserves image orientation settings applied during live and last image hold subsequent images
- Image rotation
- Image reversal (side-to-side)
- Image invert (top-to-bottom)
- On-screen orientation indicator
- Fully digital with precise 1-degree rotation increments
- On-screen collimator position indication
- PreView iris collimator
- PreView Tungsten rotatable double leaf collimator
- Adjusts collimators without X-ray exposure
- kVp range: 40 -120
- mA range: 0.2 – 10 normal mode 0.2 – 20 HLF (high level fluoro)
- Auto and manual fluoro modes
- kVp range: 40 – 120
- mA range: 0.2 – 10 normal mode, 0.2-40 HLF
- Pulse rate: 8 pps
- Pulse width: 25 ms
- Auto and manual pulsed fluoroscopy modes
- Reduces x-ray dose to patient and operator
- kVp range: 40 – 120
- mA range: Up to 75
- Automatic exposure termination and automatic image save
- Tri-mode 9”/6”/4.5” (23cm/15cm/11cm) image intensifier
- Minimum central resolution (at the monitor):
- 9” (23cm): 2.2 lp/mm
- 6” (15cm): 3.0 lp/mm
- 4.5” (11cm): 3.5 lp/mm
- DQE: 65% (typical)
- Removable Grid
- Tri-mode 12”/9”/6” (31cm/23cm/15cm) image intensifier
- Minimum central resolution (at the monitor):
- 12” (31cm): 1.6 lp/mm
- 9” (23cm): 2.2 lp/mm
- 6” (15cm): 2.6 lp/mm
- DQE: 65% (typical)
- Removable Grid
- Preset Imaging Profiles
- 9800
- General
- Orthopedic
- Spine
- Cardiac
- Vascular
- Bolus Chase
- Automatically seeks the subject anatomy anywhere within the imaging field
- Selects the optimum imaging technique by varying mA, kVp, and gain
- Automatically adjusts to anatomical size and location
- Provides uniform image quality throughout the entire image
- Smart Window
- Dynamically senses the collimator position and automatically adjusts brightness and contrast to produce high image quality.
- Smart Metal
- Allows user to adjust automatic brightness and contrast sensitivity levels to metal
- Provides optimum image quality even when metal is introduced to the field
- Tungsten Collimator
- Denser collimator limits X-ray exposure area
- Reduces scatter radiation
- Improves image detail
- 27 in (69 cm) LCD TFT color display
- Anti-glare
- Monitor mounted on an articulating arm
- 45 in (114 cm) horizontal travel
- 17 in (43.2 cm) vertical travel
- 27 in (68.8 cm) forward travel
- 5° up/5° down tilt
- Display viewable from all four sides of workstation
- Horizontal and vertical viewing angle 170°
- 450 cd/m2 maximum brightness
- Touch screen system control
- 2560 x 1440 high resolution display
- Integrated PIP window to display color DVI-D input