Philips Veradius Large C-Arm for Sale, Lease or Rent

Description

  • Monoblock
  • High tension transformer
  • Frequency: 80 kHz
  • Tube Type: Rotating Anode
  • Nominal X-ray tube voltage: 120 kV
  • Nominal focal spot values: 0.3 and 0.6 mm
  • Max. Anode Heat Content: 315 kHU
  • Max. Heat Dissipation: 73 kHU/min
  • Cooling Method: Active oil-circulation cooling
  • Inherent filter: 1.0 mm AI. equivalent
  • Integrated Beam Filter: 3.0 mm Ai +0.1mm Cu
  • Total Beam Filtration: 6.75 mm AI. eq
  • kV Range: 40-120 kV
  • mA Peak Range: 1-60 mA
  • Pulse Width: 9.3 178 ms
  • Pulse Rate: 4-8-15-optional 1-2-30
  • Full lead shutters can be rotated and moved independently.
  • Automatic Shutter Positioning (ASP) automatically positions shutters for optimal image quality
  • Integrated laser in the flat detector can be activated and deactivated at the touch of a button
  • 635 nm
  • Max. Output: <5 mW
  • Height: 66.4 – 85.7” (168.7 – 217.7 cm)
  • Width: 32.1” (84.1 cm)
  • Depth: 76.9 – 108.6” (195.6 – 275.8 cm)
  • Weight: 757 lbs. (346 kg)
  • Angulation: 140° rotation (+90/-50°) offers a maximum of projection flexibility
  • Motorized height movement: 19.3” (49 cm)
  • Longitudinal Movement: 7.0” (20 cm)
  • Panning Movement (Swivel): ±10°
  • Rotation: ±200°
  • Lowest Lateral Position: 40.4” (201.7 cm)
  • Source to Image Distance (SID) 39.1” (99.3 cm)
  • Free Space in C-Arm: 30.4” (77.2 cm)
  • C-Arm Depth: 29” (73 cm)
  • Parallel Movement: Dedicated parallel movement with rear-wheel steering, for easy positioning along operating table.
  • C-Arm stand length: 77.2” (196 cm)
  • Rotating Anode
  • High-Power Generator
  • kV range: 40-120 kV
  • mA Peak Range: 1-60 mA
  • Pulse Width: 5.6-44 ms
  • Pulse Rate: 4-8-15-optional 30
  • kV Range: 40-120 kV
  • mA Peak Range: 2-125 mA
  • Time Range: 100 and 165 ms
  • Trixell amorphous silicon detector
  • Matrix Size – 1560 x 1420 pixels
  • Active Detector Area – 26.2 x 26.2 cm/ 10.3 x 10.3″
  • Pixel pitch – 184 μm
  • Dynamic Range – 103 dB (16 bit)
  • IP Addressing: Static IP, DHCP
  • Wireless Standards Supported: IEEE802.11a/b/g
  • Number of Antennas: 2 external
  • User Configurable SSID Support:Up to 16 SSID, each with a uniqueMAC address and configurable SSIDBroadcast
  • Number of Roaming Points Supported: 16
  • Authentication Protocols: IEEE802.1xEAP-SIM, EAP-TLS, EAP-TTLS, EAP-FAST and PEAP (With choice of AES,TKIP and WEP encryption)
  • Security: IEEE802.11i WPA2, WPA withAES or TKIP encryption
  • Height: 73.6” (186 cm)
  • Width: 37.1” (94.3 cm)
  • Depth: 27.6” (70.1 cm)
  • Resolution: 1280 x 1024 pixels
  • Maximum Light Output: 650 cd/m2
  • Minimal Contrast Ratio: 1/400
  • Contrast Ratio: >700:1
  • Viewing Angle: 170° in horizontal and vertical direction.
  • Touchscreen: Offers easy access to post-processing of acquired images, patient demographics as well as PACS (left monitor)
  • Monitors: Two 19” high-brightness color LCD monitors for diagnostic image quality display

Description

  • Monoblock
  • High tension transformer
  • Frequency: 80 kHz
  • Tube Type: Rotating Anode
  • Nominal X-ray tube voltage: 120 kV
  • Nominal focal spot values: 0.3 and 0.6 mm
  • Max. Anode Heat Content: 315 kHU
  • Max. Heat Dissipation: 73 kHU/min
  • Cooling Method: Active oil-circulation cooling
  • Inherent filter: 1.0 mm AI. equivalent
  • Integrated Beam Filter: 3.0 mm Ai +0.1mm Cu
  • Total Beam Filtration: 6.75 mm AI. eq
  • kV Range: 40-120 kV
  • mA Peak Range: 1-60 mA
  • Pulse Width: 9.3 178 ms
  • Pulse Rate: 4-8-15-optional 1-2-30
  • Full lead shutters can be rotated and moved independently.
  • Automatic Shutter Positioning (ASP) automatically positions shutters for optimal image quality
  • Integrated laser in the flat detector can be activated and deactivated at the touch of a button
  • 635 nm
  • Max. Output: <5 mW
  • Height: 66.4 – 85.7” (168.7 – 217.7 cm)
  • Width: 32.1” (84.1 cm)
  • Depth: 76.9 – 108.6” (195.6 – 275.8 cm)
  • Weight: 757 lbs. (346 kg)
  • Angulation: 140° rotation (+90/-50°) offers a maximum of projection flexibility
  • Motorized height movement: 19.3” (49 cm)
  • Longitudinal Movement: 7.0” (20 cm)
  • Panning Movement (Swivel): ±10°
  • Rotation: ±200°
  • Lowest Lateral Position: 40.4” (201.7 cm)
  • Source to Image Distance (SID) 39.1” (99.3 cm)
  • Free Space in C-Arm: 30.4” (77.2 cm)
  • C-Arm Depth: 29” (73 cm)
  • Parallel Movement: Dedicated parallel movement with rear-wheel steering, for easy positioning along operating table.
  • C-Arm stand length: 77.2” (196 cm)
  • Rotating Anode
  • High-Power Generator
  • kV range: 40-120 kV
  • mA Peak Range: 1-60 mA
  • Pulse Width: 5.6-44 ms
  • Pulse Rate: 4-8-15-optional 30
  • kV Range: 40-120 kV
  • mA Peak Range: 2-125 mA
  • Time Range: 100 and 165 ms
  • Trixell amorphous silicon detector
  • Matrix Size – 1560 x 1420 pixels
  • Active Detector Area – 26.2 x 26.2 cm/ 10.3 x 10.3″
  • Pixel pitch – 184 μm
  • Dynamic Range – 103 dB (16 bit)
  • IP Addressing: Static IP, DHCP
  • Wireless Standards Supported: IEEE802.11a/b/g
  • Number of Antennas: 2 external
  • User Configurable SSID Support:Up to 16 SSID, each with a uniqueMAC address and configurable SSIDBroadcast
  • Number of Roaming Points Supported: 16
  • Authentication Protocols: IEEE802.1xEAP-SIM, EAP-TLS, EAP-TTLS, EAP-FAST and PEAP (With choice of AES,TKIP and WEP encryption)
  • Security: IEEE802.11i WPA2, WPA withAES or TKIP encryption
  • Height: 73.6” (186 cm)
  • Width: 37.1” (94.3 cm)
  • Depth: 27.6” (70.1 cm)
  • Resolution: 1280 x 1024 pixels
  • Maximum Light Output: 650 cd/m2
  • Minimal Contrast Ratio: 1/400
  • Contrast Ratio: >700:1
  • Viewing Angle: 170° in horizontal and vertical direction.
  • Touchscreen: Offers easy access to post-processing of acquired images, patient demographics as well as PACS (left monitor)
  • Monitors: Two 19” high-brightness color LCD monitors for diagnostic image quality display