Philips BV Pulsera Large C-Arm for Sale, Lease or Rent

Description

  • 80 kHz High frequency
  • 5 kW full-wave
  • Up to 120 kVp
  • Up to 60 mA for radiographic film exposures
  • Continuous fluoro boost mode up to 20 mA
  • Pulsed fluoro mode
  • Pulsed fluorography mode up to 60 mA
  • Full power from outlet:
    • 50 Hz or 60 Hz
    • 100V-20A to 240V-10A

• Rotating anode X-Ray tube
• Focal spots: 0.3 mm and 0.6 mm
• Anode heat capacity: 300,000 HU
• Anode cooling rate: 70,000 HU/min
• Housing heat capacity: 1,900,000 HU
• Anode diameter: 2.8 in
• Anode angle: 10°

• Extended processing
• Vascular functions
• Extended vascular functions
• Cardiac Pulsed functions

• Iris collimation with dual opposing lead shutters allowing elliptical, round and rectangular collimation
• Minimum beam size < 5 X 5 cm2
• Iris and shutters are continuously variable
• All functions remotely controlled from the C-Arm control panel

• Focal spot: 0.3 mm and 0.6 mm
• kVp range: 40 – 120 kVp
• mA range: 0.2 – 20 mA continuous High Definition fluoro boost mode
• Auto and manual modes
• Continuous or Pulsed operation
• APF varies mA, kVp and camera gain
• User specific APF tables

• Half Dose Fluoroscopy
• Quarter Dose Fluoroscopy
• Focal spot: 0.6 mm
• kVp range: 40 – 120 kVp
• mA range: 0.4 – 12 mA
• Pulse rate: 6.25 or 12.5 pulses per second
• Pulse width: 11 to 37 milliseconds
• Computer controlled APF, mA, kVp and camera gain

• Focal spot: 0.6 mm
• kVp range: 40 – 110 kVp
• mA range: Up to 60 mA
• Pulse rate: 3 to 30 pulses per second (optional)
• Pulse width: 8.0 / 9.5 / 11.1 milliseconds
• Computer controlled camera iris, mA, kVp, & camera gain

• Focal spot: 0.6 mm
• kVp range: 40 – 110 kVp
• mA range: 1.0 – 75 mA

• Focal spot: 0.6 mm
• kVp range: 40 – 120 kVp
• Fixed 60 mA
• 0.6 mm – mAs range: 3.2 – 125 mAs

  • 9 in Image Intensifier
    • Tri-mode 9 in/7 in/5 in image intensifier
      • 9 in.: 1.6 lp/mm
      • 7 in.: 2.1 lp/mm
      • 5 in.: 2.9 lp/mm
    • DQE: 65% (typical)
  • 12 in Image Intensifier (optional)
    • Tri-mode 12 in/9 in/7 in image intensifier
      • 12 in.: 1.2 lp/mm
      • 9 in.: 1.4 lp/mm
      • 7 in.: 2.0 lp/mm
    • DQE: 65% (typical)
  • High resolution CCD camera
  • 525 line/frame
  • Full frame capture
  • 360° motorized rotation
  • Left-right image reversal
  • Top-bottom image reversal
  • Negative mode
  • Computer controlled features: (optional)
    • Gain
    • Blanking
    • Camera iris
  • Dual 17 in high resolution, anti-glare, anti-static
  • Ambient room light sensor
  • Multi-LED X-ray “ON” indicator
  • Thermal printer
  • DICOM
  • Image Capture Device
  • Laser aiming device
  • Height: 71 / 91 in. (1805 / 2305 mm)
  • Width: 35 in. (880 mm)
  • Length: 76 in. (1930 mm)
  • Weight: 695 lbs 315 kg.
  • Height: 69 in (1760 mm)
  • Width: 32 in (800 mm)
  • Depth: 37 in (925 mm)

Description

• 80 kHz High frequency
• 7.5 kW full-wave
• Up to 120 kVp
• Up to 60 mA for radiographic film exposures
• Continuous fluoro boost mode up to 20 mA
• Pulsed fluoro mode
• Pulsed fluorography mode up to 60 mA
• Full power from outlet:
o 50 Hz or 60 Hz
o 100V-20A to 240V-10A

• Rotating anode X-Ray tube
• Focal spots: 0.3 mm and 0.6 mm
• Anode heat capacity: 300,000 HU
• Anode cooling rate: 70,000 HU/min
• Housing heat capacity: 1,900,000 HU
• Anode diameter: 2.8 in
• Anode angle: 10°

• Extended processing
• Vascular functions
• Extended vascular functions
• Cardiac Pulsed functions

• Iris collimation with dual opposing lead shutters allowing elliptical, round and rectangular collimation
• Minimum beam size < 5 X 5 cm2
• Iris and shutters are continuously variable
• All functions remotely controlled from the C-Arm control panel

• Focal spot: 0.3 mm and 0.6 mm
• kVp range: 40 – 120 kVp
• mA range: 0.2 – 20 mA continuous High Definition fluoro boost mode
• Auto and manual modes
• Continuous or Pulsed operation
• APF varies mA, kVp and camera gain
• User specific APF tables

• Half Dose Fluoroscopy
• Quarter Dose Fluoroscopy
• Focal spot: 0.6 mm
• kVp range: 40 – 120 kVp
• mA range: 0.4 – 12 mA
• Pulse rate: 6.25 or 12.5 pulses per second
• Pulse width: 11 to 37 milliseconds
• Computer controlled APF, mA, kVp and camera gain

• Focal spot: 0.6 mm
• kVp range: 40 – 110 kVp
• mA range: Up to 60 mA
• Pulse rate: 3 to 30 pulses per second (optional)
• Pulse width: 8.0 / 9.5 / 11.1 milliseconds
• Computer controlled camera iris, mA, kVp, & camera gain

• Focal spot: 0.6 mm
• kVp range: 40 – 110 kVp
• mA range: 1.0 – 75 mA

• Focal spot: 0.6 mm
• kVp range: 40 – 120 kVp
• Fixed 60 mA
• 0.6 mm – mAs range: 3.2 – 125 mAs

  • 9 in Image Intensifier
    • Tri-mode 9 in/7 in/5 in image intensifier
  • 9 in.: 1.6 lp/mm
  • 7 in.: 2.1 lp/mm
  • 5 in.: 2.9 lp/mm
    • DQE: 65% (typical)
  • 12 in Image Intensifier (optional)
    • Tri-mode 12 in/9 in/7 in image intensifier
  • 12 in.: 1.2 lp/mm
  • 9 in.: 1.4 lp/mm
  • 7 in.: 2.0 lp/mm
    • DQE: 65% (typical)
  • High resolution CCD camera
  • 525 line/frame
  • Full frame capture
  • 360° motorized rotation
  • Left-right image reversal
  • Top-bottom image reversal
  • Negative mode
  • Computer controlled features: (optional)
    o Gain
    o Blanking
    o Camera iris
  • Dual 17 in high resolution, anti-glare, anti-static
  • Ambient room light sensor
  • Multi-LED X-ray “ON” indicator
  • Thermal printer
  • DICOM
  • Image Capture Device
  • Laser aiming device
  • Height: 71 / 91 in. (1805 / 2305 mm)
  • Width: 35 in. (880 mm)
  • Length: 76 in. (1930 mm)
  • Weight: 695 lbs 315 kg.
  • Height: 69 in (1760 mm)
  • Width: 32 in (800 mm)
  • Depth: 37 in (925 mm)

REQUEST A QUOTE!