Siemens Arcadis Orbic 3D Large C-Arm for Sale, Lease or Rent

Description

  • Isocentric C-Arm movement with integrated cables and electromagnetic brakes
  • Orbital movement: 190° (± 95°)
  • Angulation: ± 190°
  • Horizontal Movement: 20 cm
  • Immersion Depth: 73 cm
  • Swivel Range: ± 10°
  • Vertical Travel: 40 cm
  • Source: I.I. distance 98 cm
  • Free Space: 78 cm
  • Max. pulsed output: 2.3 kW
  • Inverter control frequency: 15 kHz to 30 kHz
  • kV range: 40 kV to 110 kV
  • Fluoroscopy: 0.2 mA to 15.2 mA (max. 1000 W)
  • Digital Radiography: 0.2 mA to 23 mA (max. 1000 W)
  • Pulsed Fluoroscopy: up to 23 mA
  • Pulse width min. 7 ms Pulse rate up to 8 f/s, up to 15 f/s*
  • Power Mode enables temporary max. output in continuous fluoroscopy and pulsed fluoroscopy
  • Monitor Size: 18″ dual TFT flat-panel monitors
  • H x W x D of C-Arm Frame, cm (in): 183 x 80 x 215 (72 x 31.5 x 84.5)
  • Video Storage: Digital memory, Digital memory, disk
  • Image Matrix Size: 2.3
  • Last Taken Image hold: Yes
  • Frame Integration: 0-32 frames
  • Max. # of Images: 10,000 on hard disk; ~300 on CD; both are standard
  • Temperature Range: + 15°C to + 35°C
  • Relative Humidity: 15% to 75%, non-condensing
  • Barometric Pressure: 700 hPa to 1060 hPa
  • Diameter (Wheels): 9, 6 in
  • H x W x D of C-Arm Frame: 72 x 31.5 x 84.5 in
  • Weight: Chassis 765lbs, monitor cart 418lbs
  • Cassette Holder: 24 x 3024 x 30 cm
  • Free Space (C-Arm): 31 in
  • Depth (PA Gantry): 29 in
  • Panning Movement (C-Arm): 10 in
  • Rotation (C-Arm): 95 in
  • Horizontal Travel (C-Arm): 7.9
  • Pivot Rotation (C-Arm): 190
  • Power Requirements: 100 V, 110 V, 120 V, 127 V, 200 V, 230 V, 240 V, (± 10%), 50/60 Hz (± 1 Hz)
  • Device Fusing (Internal): 100 V to 127 V 20 A slow-blow fuse 200 V to 240 V 15 A slow-blow fuse
  • Pulses Per Sec (Monitor): p to 15
  • Ma Range (Imaging System): 0.2 – 23
  • Pulsed Fluoroscopy (X-Ray Generator): Yes
  • Kv Range (X-Ray Generator): 40
  • Aec (X-Ray Generator): mAs
  • Tube Power Rating, kw @ 100 kvp (Maximum Output): 2.3
  • Power Requirements: 110-240 VAC

Description

  • Isocentric C-Arm movement with integrated cables and electromagnetic brakes
  • Orbital movement: 190° (± 95°)
  • Angulation: ± 190°
  • Horizontal Movement: 20 cm
  • Immersion Depth: 73 cm
  • Swivel Range: ± 10°
  • Vertical Travel: 40 cm
  • Source: I.I. distance 98 cm
  • Free Space: 78 cm
  • Max. pulsed output: 2.3 kW
  • Inverter control frequency: 15 kHz to 30 kHz
  • kV range: 40 kV to 110 kV
  • Fluoroscopy: 0.2 mA to 15.2 mA (max. 1000 W)
  • Digital Radiography: 0.2 mA to 23 mA (max. 1000 W)
  • Pulsed Fluoroscopy: up to 23 mA
  • Pulse width min. 7 ms Pulse rate up to 8 f/s, up to 15 f/s*
  • Power Mode enables temporary max. output in continuous fluoroscopy and pulsed fluoroscopy
  • Monitor Size: 18″ dual TFT flat-panel monitors
  • H x W x D of C-Arm Frame, cm (in): 183 x 80 x 215 (72 x 31.5 x 84.5)
  • Video Storage: Digital memory, Digital memory, disk
  • Image Matrix Size: 2.3
  • Last Taken Image hold: Yes
  • Frame Integration: 0-32 frames
  • Max. # of Images: 10,000 on hard disk; ~300 on CD; both are standard
  • Temperature Range: + 15°C to + 35°C
  • Relative Humidity: 15% to 75%, non-condensing
  • Barometric Pressure: 700 hPa to 1060 hPa
  • Diameter (Wheels): 9, 6 in
  • H x W x D of C-Arm Frame: 72 x 31.5 x 84.5 in
  • Weight: Chassis 765lbs, monitor cart 418lbs
  • Cassette Holder: 24 x 3024 x 30 cm
  • Free Space (C-Arm): 31 in
  • Depth (PA Gantry): 29 in
  • Panning Movement (C-Arm): 10 in
  • Rotation (C-Arm): 95 in
  • Horizontal Travel (C-Arm): 7.9
  • Pivot Rotation (C-Arm): 190
  • Power Requirements: 100 V, 110 V, 120 V, 127 V, 200 V, 230 V, 240 V, (± 10%), 50/60 Hz (± 1 Hz)
  • Device Fusing (Internal): 100 V to 127 V 20 A slow-blow fuse 200 V to 240 V 15 A slow-blow fuse
  • Pulses Per Sec (Monitor): p to 15
  • Ma Range (Imaging System): 0.2 – 23
  • Pulsed Fluoroscopy (X-Ray Generator): Yes
  • Kv Range (X-Ray Generator): 40
  • Aec (X-Ray Generator): mAs
  • Tube Power Rating, kw @ 100 kvp (Maximum Output): 2.3
  • Power Requirements: 110-240 VAC

REQUEST A QUOTE!